Vertiv SmartRow 2 In-Row Cooling Unit | 2 Racks | 10 kW 208V Single-Phase
The Vertiv SmartRow 2 is a comprehensive rack-based integrated IT infrastructure solution designed for organizations requiring efficient thermal management across 2-rack configurations. This in-row cooling unit delivers 10 kW capacity at 208V single-phase (2N), making it ideal for mid-scale data centers, edge computing environments, and enterprise server rooms. The system combines cold air containment and hot air containment technologies to maximize cooling efficiency, reduce energy consumption, and maintain optimal operating temperatures for critical IT equipment. Perfect for IT managers and data center operators seeking to eliminate hot spots while improving power distribution and infrastructure density.
Key Features
-
In-row cooling unit — Precision thermal management positioned directly within rack infrastructure
-
Cold air containment — Isolates cool air delivery to prevent mixing with ambient room temperature
-
Hot air containment — Captures and recirculates exhaust air for improved efficiency
- 10 kW cooling capacity — Handles demanding single-phase 208V power requirements
- 2-rack configuration — Optimized footprint for compact data center deployments
- Single-phase 208V operation — Simplified electrical integration without three-phase requirements
- Integrated infrastructure design — Combines cooling, containment, and power distribution in one solution
- Energy-efficient thermal control — Reduces overall data center cooling costs and environmental impact
Technical Specifications
| Specification |
Details |
| Manufacturer |
Vertiv |
| Product Series |
SmartRow 2 |
| Part Number |
SR2N02010PAA1 |
| Rack Configuration |
2 Racks |
| Cooling Capacity |
10 kW |
| Electrical Input |
208V Single-Phase (2N) |
| Cooling Unit Type |
In-Row Cooling Unit |
| Air Containment |
Cold Air Containment + Hot Air Containment |
| Infrastructure Type |
Integrated Rack-Based Solution |
Frequently Asked Questions
What is an in-row cooling unit and how does it improve data center efficiency?
An in-row cooling unit is positioned directly within the server rack infrastructure to deliver precision cooling at the point of heat generation. This approach eliminates the need for room-wide air conditioning, reduces energy waste, and prevents hot spots that can damage equipment. The Vertiv SmartRow 2's in-row design significantly improves thermal efficiency compared to traditional perimeter cooling systems.
How do cold air containment and hot air containment work together?
Cold air containment isolates cool air delivery to server intake areas, preventing it from mixing with warm ambient air. Hot air containment captures exhaust air from equipment and either recirculates it or directs it to cooling units. Together, these technologies create a closed-loop thermal management system that maximizes cooling effectiveness and reduces energy consumption in your data center.
Is the Vertiv SmartRow 2 suitable for edge computing environments?
Yes. The 10 kW capacity at 208V single-phase makes the SmartRow 2 ideal for edge computing deployments, remote offices, and smaller data centers where three-phase power may not be available. Its integrated infrastructure design and compact 2-rack footprint provide efficient thermal management without requiring extensive facility modifications.
What are the power distribution benefits of this integrated infrastructure solution?
The Vertiv SmartRow 2 combines cooling, containment, and power distribution into a single integrated system, simplifying installation and reducing cable complexity. This approach improves airflow predictability, enhances equipment reliability, and streamlines maintenance compared to separate cooling and power systems.