✅⚠️DO NOT ORDER WITHOUT CONFIRMING STOCK. This item has limited availability. Contact us via chat or sales@tecisoft.com to verify before purchasing. Unconfirmed orders may be canceled.
Description
2-2.4kW Single-Phase Hot-Swap PDU, 200-240V 10A Outlets (8-C13), 2-C14, 200-240V Input, 6 ft. (1.83 m) Cords 2U Rack-Mount
Tripp Lite PDUBHV10 2-2.4kW Single-Phase Hot-Swap PDU, 200-240V 10A Outlets (8-C13), 2-C14, 200-240V Input, 6 ft. (1.83 m) Cords 2U Rack-Mount. PDU types: Basic, Rack capacity: 2U, Mounting: Horizontal. AC outlets quantity: 9 AC outlet(s), AC outlet types: C13 coupler, Power plug: C14 coupler. Cable length: 1.83 m, Certification: UL60950 (USA), CSA (Canada), CE (IEC60950). Nominal input voltage: 200-240 V, Maximum current: 10 A, AC input frequency: 50 - 60 Hz. Width: 439.9 mm, Depth: 77 mm, Dimensions (WxDxH): 440 x 77 x 87 mm
Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads PDUBHV10 is universally compatible with any Tripp Lite or other brand of 200-240V UPS rated up to 1500VA with a C14 input cable option 2U horizontal rackmount form factor compatible with 2 or 4 post racks Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual) Pair of detachable PDU input cables connect to separate Utility and UPS power sources (2 C13-C14 interconnect cables included - user supplied alternate cabling supported) 8 C13 outlets support critical networking loads in both Utility and UPS operating modes One additional C13 pass-through outlet supports UPS input power cord Dual input power cables support PDU connection to separate Utility and UPS power sources Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the UPS system is removed and replaced with a fresh one Once the new UPS is up and running with all connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment
General Information
Manufacturer
Tripp Lite by Eaton
Manufacturer Part Number
PDUBHV10
Manufacturer Website Address
https://tripplite.eaton.com/
Brand Name
Tripp Lite by Eaton
Product Model
PDUBHV10
Product Name
PDUBHV10 PDU Dual Srce Hot Swap 200-240V 10A 8 Out
Product Type
PDU
UPC
37332153906
Height
3.4"
Width
17.3"
Depth
3"
Weight (Approximate)
7.70 lb
Miscellaneous
Package Contents
PDUBHV10 PDU Dual Srce Hot Swap 200-240V 10A 8 Out
2U Mounting Brackets
Set of 2 x C13-C14 Interconnect Cables
User Manual with Warranty Information
Environmentally Friendly
Yes
Warranty
Limited Warranty
2 Year
Roll over image to zoom inClick on image to zoom
/
Canada: Prices in CAD. Ships nationwide in 2–5 business days. GST/HST/PST calculated at checkout.
Shipping policy.