Server Technology PRO2 Smart POPS PDU C2LG36TE-YQME2M66 - Link - power distribution unit expansion module (rack-mountable) - AC 208 V - 17.3 kW - 3-phase WYE (star) - Ethernet 10/100, RS-232 - input: IEC 60309 3P+N+G - output connectors: 36 (24 x IEC 60320 C13, 12 x IEC 60320 Cx)
-
Network monitoring
The PRO2 hot-swappable network card provides for HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
-
Hot-swap network card
Network access is ensured when power is lost to the Master unit with backup power provided by the primary link unit.
-
Star multi-linking
PRO2 provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
-
Temperature/humidity monitoring
PRO2 Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
-
Auto-flip current display
Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
-
Per-inlet power sensing
Meets ANSI C12.1 for billing-grade accuracy of current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
-
Branch current monitoring
PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
-
Branch circuit protection
PRO2 meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
-
Alternating phase
3-phase power is wired in an alternating fashion per outlet for simplified load balancing, reduced cord lengths, and better airflow.
-
High retention outlets
PRO2 receptacles have high retention and are compatible with P-Lock type power cords.
-
High temperature rating
This product has been tested and approved for safe and reliable operation in 60°C (140°F) data center environments.
The Server Technology PRO2 POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS and POPS technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output.
- Network monitoring
- Hot-swap network card
- Star multi-linking
- Temperature/humidity monitoring
- Auto-flip current display
- Per-inlet power sensing
- Branch current monitoring
- Branch circuit protection
- Alternating phase
- High retention outlets
- High temperature rating