Server Technology PRO1 Smart PDU C1S24SP-2CAA4A6 - Master - power distribution unit (rack-mountable) - AC 208 V - 5 kW - Ethernet 10/100, RS-232 - input: NEMA L6-30P - output connectors: 24 (18 x IEC 60320 C13, 6 x IEC 60320 Cx)
-
HDOT Cx
Cx is the future-ready hybrid of the C13 and C19 outlets accommodating both C20 and C14 plugs.
-
Network monitoring
Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
-
Hot-swap network card
Network access is ensured when power is lost to the master unit with backup power provided by the primary link unit.
-
Star multilinking
Provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
-
Temperature / humidity monitoring
Master and link units each support two external 3 m T/H probes. Receive SNMP-based alerts and email notifications.
-
Auto-flip current display
Easy-to-read LED display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
-
Per Input Power Sensing
Billing-grade accuracy of current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
-
Branch circuit protection
This PDU meets high requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
-
High-retention locking outlets
Receptacles have high retention and are compatible with P-Lock type power cords.
-
High temperature rating
This product is safe and reliable operation in 60°C data center environments.
The Server Technology PRO1 Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack / cabinet. The integral PIPS technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements, are accessible through the built-in web and CLI interfaces as well as through SNMP. The PRO1 Smart "Master" PDU can be connected to as many as three PRO1 Smart "Link" PDU to extend the network access to the redundant or secondary power feed without the risks of a daisy-chain linking configuration.
- HDOT Cx
- Network monitoring
- Hot-swap network card
- Star multilinking
- Temperature / humidity monitoring
- Auto-flip current display
- Per Input Power Sensing
- Branch circuit protection
- High-retention locking outlets
- High temperature rating