Raritan PXC-1862V-K1 Rack PDU — 208V Single-Phase Power Distribution for High-Density Data Centers
The Raritan PXC-1862V-K1 rack PDU delivers reliable single-phase 208V AC power distribution to demanding IT environments. With 36 outlets (30 IEC C13 and 6 IEC C19) and 5.0kVA capacity at 24A rated output, this 208V 1-phase PDU is engineered for high-density server racks, blade chassis, and enterprise networking equipment. Built for mission-critical deployments, the PXC-1862V-K1 ensures consistent power availability while maximizing outlet density in space-constrained data center installations.
Key Features
- 36 total outlets: 30 × IEC C13 + 6 × IEC C19 connectors
- Single-phase 208V AC input with NEMA L6-30P plug
- 5.0kVA maximum power capacity at 24A rated
- High-density outlet configuration for compact rack mounting
- Supports mixed IT equipment loads (servers, switches, UPS units)
- Vertical or horizontal mounting flexibility
- Durable construction for 24/7 data center operation
Technical Specifications
| Specification |
Details |
| Manufacturer |
Raritan |
| Model |
PXC-1862V-K1 |
| Input Voltage |
208V AC, Single-Phase |
| Input Current (Rated) |
24A |
| Input Current (Maximum) |
30A |
| Power Capacity |
5.0kVA |
| C13 Outlets |
30 |
| C19 Outlets |
6 |
| Input Connector |
NEMA L6-30P |
| Mounting |
Vertical or Horizontal Rack Mount |
Frequently Asked Questions
What is the difference between C13 and C19 outlets on this rack PDU?
The PXC-1862V-K1 includes 30 C13 outlets for standard servers and networking equipment, plus 6 C19 outlets for high-power devices like blade chassis and large UPS systems. C19 connectors support higher current draw, making them ideal for demanding equipment in your data center.
Can this 208V PDU handle my server rack power requirements?
Yes. With 5.0kVA capacity and 24A rated output, the PXC-1862V-K1 supports typical server rack loads including multiple 1U/2U servers, network switches, and storage arrays. Verify your total equipment power draw does not exceed 5.0kVA for optimal performance.
What type of input power connection does the PXC-1862V-K1 require?
This rack PDU uses a NEMA L6-30P input plug, a standard 208V single-phase connector found in most data center power distribution infrastructure. Ensure your facility's power source matches this connector type before installation.
Is the PXC-1862V-K1 suitable for high-density server environments?
Absolutely. The 36-outlet configuration with mixed C13/C19 connectors maximizes power outlet density in compact racks, making it ideal for virtualized environments, blade server deployments, and consolidated IT infrastructure where space efficiency is critical.