Raritan PX3-5871I2U-F1N2 Intelligent Rack PDU
The Raritan PX3-5871I2U-F1N2 Rack PDU is purpose-built for high-density data centers requiring precise outlet-level power monitoring and control. This intelligent power distribution unit delivers real-time energy metering across 48 outlets in a zero U vertical form factor, making it ideal for facilities managing 3-phase 400V environments with strict power budgeting and equipment protection requirements. IT managers, data center operators, and facility engineers rely on this intelligent PDU to optimize power distribution, prevent overloads, and reduce downtime through advanced monitoring capabilities.
Key Features
- 48 IEC C13 outlets with individual outlet-level metering and switching
- Zero U vertical design maximizes rack space efficiency
- 3-phase 400V input with up to 28.8kVA power capacity
- Cascading support for up to 16 PDUs via single Ethernet or USB connection
- Onboard embedded processor for autonomous operation and local control
- Dual Ethernet ports for redundant network connectivity
- Real-time energy monitoring and advanced power analytics
- Remote outlet control and power cycling capabilities
- Comprehensive electrical protection and surge suppression
Technical Specifications
| Specification |
Details |
| Manufacturer |
Raritan |
| Model Number |
PX3-5871I2U-F1N2 |
| Form Factor |
Zero U Vertical Rack PDU |
| Input Voltage |
3-phase 400V |
| Maximum Power Capacity |
28.8kVA |
| Outlet Count |
48 x IEC C13 |
| Monitoring |
Outlet-level metering and switching |
| Network Connectivity |
Dual Ethernet ports |
| Cascading |
Up to 16 PDUs via Ethernet or USB |
| Processor |
Onboard embedded processor |
Frequently Asked Questions
What is an intelligent rack PDU and how does it improve data center efficiency?
An intelligent rack PDU like the Raritan PX3-5871I2U-F1N2 provides real-time outlet-level power monitoring and remote control capabilities. This enables data center operators to track power consumption per device, identify overloaded circuits before failures occur, and remotely power cycle equipment—reducing operational costs and preventing costly downtime.
Can the Raritan PX3-5871I2U-F1N2 be integrated with existing data center management systems?
Yes. The dual Ethernet ports and cascading support for up to 16 PDUs allow seamless integration into existing infrastructure management platforms. The onboard embedded processor enables autonomous operation while supporting network-based monitoring and control through standard protocols.
What makes a zero U vertical PDU design beneficial for high-density environments?
The zero U vertical form factor of this intelligent power distribution unit maximizes usable rack space by mounting vertically without consuming horizontal U-space. This is critical in high-density 3-phase 400V data centers where space is premium and power distribution must scale efficiently.
How does outlet-level metering help prevent power-related equipment failures?
Outlet-level metering provides granular visibility into power draw per connected device. This allows proactive identification of circuits approaching capacity limits, enabling administrators to redistribute loads and prevent circuit breakers from tripping—ensuring continuous operation of critical infrastructure.