Raritan PX3-1901I2U-N1 Zero U Vertical PDU
The Raritan PX3-1901I2U-N1 is a high-capacity Zero U vertical power distribution unit designed for dense data center and server room environments where rack space is premium. This 3-phase 415V PDU delivers 17.3kVA of managed power with metered monitoring, making it ideal for organizations requiring precise power allocation across 48 outlets without consuming vertical rack units. With 42 C13 and 6 C19 connectors, this vertical PDU accommodates both standard servers and high-power equipment in a single, space-efficient solution.
Key Features
-
Zero U Design: Mounts vertically outside the rack, preserving all 42U of usable rack space
-
48 Total Outlets: 42x C13 connectors for standard servers + 6x C19 for high-power devices
-
3-Phase 415V Input: 32A rated capacity (24A per phase) for balanced three-phase power distribution
-
17.3kVA Power Rating: Supports demanding multi-server deployments with headroom for growth
-
Unit Metering: Real-time power monitoring and consumption tracking at the PDU level
-
IEC 60309 3P+N+E 6h Plug: Industrial-grade 32A connector for secure, reliable power input
-
Top-Feed Configuration: Flexible cable management with overhead power entry
-
Vertical Mounting: Compact footprint ideal for edge computing and co-location facilities
Technical Specifications
| Manufacturer |
Raritan |
| Model |
PX3-1901I2U-N1 |
| Form Factor |
Zero U Vertical PDU |
| Input Phase |
3-Phase AC |
| Input Voltage |
415V AC |
| Input Current Rating |
32A (24A per phase) |
| Power Capacity |
17.3kVA |
| Outlet Configuration |
42x IEC 60320 C13 + 6x IEC 60320 C19 |
| Total Outlets |
48 |
| Input Connector |
IEC 60309 3P+N+E 6h 32A |
| Cable Entry |
Top-Feed |
| Monitoring |
Unit-Level Metering |
| Mounting |
Vertical (Outside Rack) |
Frequently Asked Questions
What is a Zero U vertical PDU and why should I use one?
A Zero U vertical PDU mounts outside your server rack, preserving all 42U of internal rack space for revenue-generating equipment. The Raritan PX3-1901I2U-N1 is perfect for data centers with space constraints, allowing you to add 48 power outlets without sacrificing rack capacity.
Can this PDU handle mixed server loads with C13 and C19 outlets?
Yes. The 48-outlet configuration includes 42x C13 connectors for standard 1U/2U servers and 6x C19 connectors for high-power equipment like blade servers or storage arrays. The 17.3kVA capacity and 3-phase 415V input ensure balanced power distribution across diverse workloads.
What does unit metering provide in a PDU?
Unit metering on the Raritan PX3-1901I2U-N1 tracks total power consumption at the PDU level, enabling real-time visibility into facility power usage, capacity planning, and cost allocation across departments or customers in multi-tenant environments.
Is the IEC 60309 3P+N+E 6h plug compatible with standard data center power infrastructure?
The IEC 60309 3P+N+E 6h 32A connector is an industrial-grade plug standard widely used in European and international data centers. Verify your facility's power distribution infrastructure supports this connector type before deployment.