Raritan PX3-1170U Unit Metered Rack PDU
The Raritan PX3-1170U is a unit metered rack PDU engineered for data centers and IT environments requiring precise power distribution and energy monitoring. This intelligent PDU delivers 208V, 5.8kVA, 20A three-phase power in a compact 0U vertical form factor, making it ideal for cabinet-mounted installations where space is critical. With 30 outlets—including 21 C13, 6 C19, and 3 NEMA 5-20R connectors—it accommodates diverse equipment types while providing advanced metering at both inlet and circuit levels. Organizations use this metered PDU to track energy consumption in real-time, balance loads across phases, and optimize capacity planning for improved reliability and cost control.
Key Features
-
Unit metering at inlet and PDU circuit level for granular energy visibility
-
30 mixed outlets: 21 C13, 6 C19, and 3 NEMA 5-20R for flexible equipment connectivity
-
208V, 5.8kVA, 20A three-phase power delivery with balanced load distribution
-
0U vertical form factor maximizes cabinet space utilization
-
Embedded processor enables local monitoring and intelligent power management
-
Cascading support for up to 16 PDUs over single Ethernet or USB connection
-
Real-time energy tracking for capacity planning and cost optimization
-
Phase balancing capabilities reduce strain on electrical infrastructure
Technical Specifications
| Specification |
Details |
| Manufacturer |
Raritan |
| Model |
PX3-1170U |
| Form Factor |
0U Vertical Rack PDU |
| Input Voltage |
208V, 3-Phase |
| Power Rating |
5.8kVA |
| Current Rating |
20A per phase |
| Total Outlets |
30 (21 C13, 6 C19, 3 NEMA 5-20R) |
| Metering Type |
Unit metered (inlet + circuit level) |
| Management Interface |
Embedded processor with Ethernet/USB |
| Cascading Capability |
Up to 16 PDUs per connection |
| Monitoring Features |
Real-time energy usage, phase balancing, load distribution |
Frequently Asked Questions
What is a unit metered rack PDU and why do I need one?
A unit metered rack PDU provides detailed power consumption data at both the inlet and individual circuit levels. This enables data center operators to monitor energy usage in real-time, identify power-hungry equipment, balance loads across phases, and make informed decisions about capacity planning and cost optimization.
How many devices can I connect to the Raritan PX3-1170U?
The PX3-1170U features 30 outlets total: 21 C13 outlets (standard for servers and networking equipment), 6 C19 outlets (for high-power devices), and 3 NEMA 5-20R outlets (for general-purpose equipment). This mixed configuration accommodates diverse equipment types in modern data centers.
Can I manage multiple PX3-1170U PDUs together?
Yes. The PX3-1170U supports cascading up to 16 units over a single Ethernet or USB connection, allowing centralized monitoring and management of multiple metered PDUs from a single interface. This simplifies administration in large-scale deployments.
What are the power specifications for the PX3-1170U?
The PX3-1170U delivers 208V, 5.8kVA, 20A three-phase power in a 0U vertical form factor. Its three-phase design enables efficient load balancing and is ideal for cabinet installations where vertical space is limited.