Raritan Dominion PX2-2725 Intelligent Rack PDU
The Raritan Dominion PX2-2725 is an enterprise-grade intelligent rack PDU engineered for high-density data centers requiring reliable power distribution across demanding IT environments. With 36 outlets and 8.6kVA capacity, this 208V 3-phase PDU delivers exceptional power management for server racks, storage systems, and network infrastructure. Ideal for organizations needing granular outlet control, real-time power monitoring, and zero-U vertical mounting in space-constrained facilities, the PX2-2725 combines intelligent metering with enterprise reliability to optimize uptime and reduce operational costs.
Key Features
- 36 mixed IEC 60320 C13 and C19 outlets for flexible device connectivity
- 8.6kVA power capacity with 208V AC 3-phase input
- Zero U vertical form factor for space-efficient rack mounting
- NEMA L21-30P plug connector for secure power input
- Intelligent power monitoring and outlet-level control
- Enterprise-grade reliability for mission-critical data center operations
- Real-time power consumption tracking and alerts
- Remote management capabilities for distributed IT teams
Technical Specifications
| Specification |
Details |
| Manufacturer |
Raritan |
| Model |
PX2-2725 |
| Product Series |
Dominion PX-2000 |
| Outlet Count |
36 outlets (mix of C13 and C19) |
| Power Capacity |
8.6kVA |
| Input Voltage |
208V AC 3-phase |
| Input Connector |
NEMA L21-30P |
| Form Factor |
Zero U vertical |
| Outlet Types |
IEC 60320 C13, IEC 60320 C19 |
| Power Management |
Intelligent metering and control |
| Application |
High-density data center power distribution |
Frequently Asked Questions
What is an intelligent rack PDU and why do I need one?
An intelligent rack PDU provides outlet-level power monitoring, remote on/off control, and real-time energy tracking for data center equipment. The Raritan Dominion PX2-2725 enables IT teams to manage power distribution remotely, prevent overloads, and reduce downtime through granular visibility into power consumption across all 36 outlets.
Can the PX2-2725 support high-density server environments?
Yes. With 36 outlets and 8.6kVA capacity, the PX2-2725 is specifically designed for high-density data centers. Its mix of C13 and C19 connectors accommodates both standard servers and power-hungry equipment, while the Zero U form factor maximizes rack space utilization.
What power input does the Dominion PX2-2725 require?
The PX2-2725 requires 208V AC 3-phase input with a NEMA L21-30P connector. This three-phase configuration is standard in enterprise data centers and provides balanced power distribution for optimal performance and efficiency.
How does the Zero U design benefit my data center?
The Zero U vertical mounting design allows the Raritan Dominion PX2-2725 to be installed without consuming rack units, preserving valuable vertical space for revenue-generating equipment while maintaining full power distribution and monitoring capabilities.