The Panduit P06D18M Horizontal SmartZone G5 Monitored Input PDU is engineered for data center managers, IT professionals, and facility operators who require high-power intelligent power distribution unit capabilities with comprehensive monitoring. This horizontal power distribution unit delivers:
-
6x C19 outlets for three phase power distribution supporting high-power server and network equipment with maximum compatibility
-
SmartZone G5 monitored input functionality enabling real-time power consumption analytics and comprehensive energy monitoring
-
Horizontal mounting design optimized for efficient rack installation and maximum space utilization in enterprise environments
-
Three phase power distribution unit capabilities providing robust power delivery for demanding data center applications
Key Features
-
Intelligent power distribution unit to provide comprehensive input-level metering and advanced monitoring capabilities
-
6x C19 outlet configuration supporting high-power equipment requiring 16A connections for maximum compatibility
- Optimized for three phase power distribution ensuring efficient power delivery and load balancing across phases
- Consistent monitored input PDU functionality delivering accurate power consumption data and energy analytics
-
SmartZone G5 intelligence enabling network monitoring, SNMP management, and integration with DCIM systems
Technical Specifications
| Manufacturer |
Panduit |
| Model Number |
P06D18M |
| Type |
Horizontal SmartZone G5 Monitored Input PDU |
| Outlet Configuration |
6x C19 outlets |
| Power Configuration |
Three phase power distribution |
| Monitoring |
Input-level metering and environmental sensors |
| Form Factor |
Horizontal mounting design |
| Series |
SmartZone G5 |
| Management |
SmartZone G5 web interface, SNMP v1/v2c/v3, ModBus TCP |
| Compatible Systems |
High-power servers, network equipment, telecommunications gear requiring C19/C20 connections |
Frequently Asked Questions
Q: What are the benefits of horizontal PDU mounting?
A: The horizontal power distribution unit design provides easy front-access installation, efficient cable management, and optimal space utilization in standard rack configurations while maintaining accessibility for maintenance and monitoring.
Q: How do C19 outlets support high-power equipment?
A: 6x C19 outlets accommodate 16A high-power equipment connections (C20 plugs), making this PDU ideal for servers, blade chassis, and network equipment requiring higher power capacity than standard C13 connections.
Q: What monitoring capabilities does SmartZone G5 provide?
A: The SmartZone G5 monitored input PDU offers input-level current, voltage, and power monitoring across all phases, environmental sensors for temperature and humidity, real-time analytics, and customizable alerting for proactive infrastructure management.
Q: Is this suitable for three-phase data center applications?
A: Yes, this three phase power distribution unit is specifically designed for enterprise data centers requiring high-power distribution, load balancing across phases, and comprehensive monitoring for mission-critical applications.
Panduit P06D18M Horizontal SmartZone G5 Monitored Input PDU with 6x C19 outlets. Three phase power distribution for data centers.