This POD maintenance bypass unit is perfect for data center technicians, facility managers, and IT professionals requiring uninterrupted power during UPS maintenance operations. Our output distribution unit delivers:
-
Maintenance bypass functionality enabling safe UPS servicing without power interruption
-
POD configuration design optimizing space utilization in critical power installations
-
GXT3 UPS compatibility ensuring seamless integration with Vertiv power systems
-
Professional power distribution maintaining reliable outlet configuration during maintenance
Key Features
-
L14-30P input connection providing secure 30-amp power feed capability
-
Dual L6-30R output receptacles supporting multiple equipment power requirements
-
Maintenance bypass operation enabling safe UPS maintenance without downtime
-
5/6KVA power capacity supporting high-density equipment installations
-
Rack mountable design optimizing data center space utilization
-
Professional grade construction meeting critical facility power standards
Technical Specifications
| Manufacturer |
Vertiv |
| Model Number |
PD2-003 |
| Type |
GXT3 POD Maintenance Bypass Output Distribution Unit |
| Power Capacity |
5/6KVA |
| Input Configuration |
L14-30P plug (30-amp) |
| Output Configuration |
2x L6-30R receptacles |
| Additional Outlets |
4x additional receptacles |
| Bypass Function |
Maintenance bypass capability |
| Compatible UPS |
Vertiv GXT3 UPS systems |
| Mount Type |
Rack mount power distribution |
| Application |
Critical facility power distribution
|
| Installation |
Professional data center deployment |
Frequently Asked Questions
Q: How does the maintenance bypass function work on this POD unit?
A: The maintenance bypass allows technicians to safely service connected UPS equipment while maintaining power to critical loads. This output distribution unit enables seamless transition between UPS and bypass power sources.
Q: What UPS systems are compatible with the PD2-003 POD unit?
A: This POD maintenance bypass is specifically designed for Vertiv GXT3 UPS systems rated at 5/6KVA capacity. The unit ensures optimal integration and performance with compatible Vertiv power protection equipment.
Q: What are the power specifications for input and output connections?
A: The unit features an L14-30P input for 30-amp power feed and provides 2x L6-30R output receptacles plus 4 additional outlets. This configuration supports flexible power distribution for multiple equipment types.
Q: Is this unit suitable for rack mount installations?
A: Yes, this power distribution unit features rack mountable design optimized for data center deployments. The POD configuration maximizes space efficiency while maintaining professional power distribution capabilities.
Vertiv PD2-003 GXT3 POD maintenance bypass output distribution unit with 5/6KVA capacity, L14-30P input and L6-30R outlets for UPS maintenance operations.