This professional Eaton ATS rack PDU is perfect for data center managers, IT professionals, and network administrators requiring reliable automatic transfer switch power distribution solutions. Our advanced 1U rack PDU delivers:
-
Dual input power redundancy ensuring continuous operation during power source failures
-
Automatic transfer switching providing seamless failover protection for critical equipment
-
Single-phase 24A capacity supporting high-power rack mount devices
-
Compact 1U design maximizing valuable rack space efficiency
Key Features
-
Dual L5-30P input connections enabling redundant power source connectivity
-
Automatic transfer switch technology providing instant failover without interruption
-
2.88 kW maximum power capacity supporting demanding server configurations
-
Single L5-30R output delivering clean, conditioned power to equipment
-
110-125V single-phase operation compatible with standard North American power systems
-
9-foot power cord providing flexible installation options
-
1U rack mount form factor optimizing space utilization in server racks
Technical Specifications
| Manufacturer |
Eaton |
| Model Number |
PWATSL530007 |
| Type |
ATS Rack PDU (Automatic Transfer Switch) |
| Rack Height |
1U (1.75 inches) |
| Input Connections |
(2) L5-30P plugs |
| Output Connection |
(1) L5-30R receptacle |
| Maximum Power |
2.88 kW |
| Voltage Rating |
110-125V |
| Current Rating |
24 Amperes |
| Phase |
Single-Phase |
| Power Cord Length |
9 feet (2.7 meters) |
| Transfer Time |
< 20 milliseconds |
| Compatible Applications |
Data Centers, Server Rooms, Network Equipment |
Frequently Asked Questions
Q: How does the automatic transfer switch function work?
A: This Eaton ATS rack PDU continuously monitors both input power sources. When the primary source fails or falls outside acceptable parameters, the unit automatically transfers the load to the secondary source in less than 20 milliseconds, ensuring uninterrupted power distribution to your critical equipment.
Q: What equipment is compatible with this dual input power distribution unit?
A: This 1U rack PDU is ideal for servers, network switches, storage arrays, and other mission-critical equipment requiring L5-30R power connections. It's specifically designed for data center power distribution applications where power redundancy is essential.
Q: Can this unit be used with standard UPS systems?
A: Yes, this automatic transfer switch PDU is commonly deployed with dual UPS configurations or UPS plus utility power setups. The dual L5-30P inputs can connect to separate power sources, providing comprehensive backup power redundancy for your critical infrastructure.
Q: What makes this different from a standard PDU?
A: Unlike basic power distribution units, this ATS PDU features intelligent transfer switching technology. It actively monitors power quality and automatically switches between sources when needed, eliminating manual intervention and reducing downtime in mission-critical environments.
Eaton ATS 1U Rack PDU PWATSL530007 with automatic transfer switch technology. Dual L5-30P inputs, 2.88kW capacity, seamless failover protection.