This ATS rack PDU is perfect for data center administrators and IT professionals who need reliable automatic transfer switch capabilities for critical server equipment. Our Eaton ATS ePDU delivers:
-
Switched power distribution unit with seamless failover between power sources
-
Dual C20 input configuration for redundant power connectivity
-
1U rack mount design ensuring efficient space utilization
-
3.33 kW maximum capacity for enterprise power management
Key Features
-
Automatic transfer switch technology for uninterrupted power continuity
-
Switched rack power distribution unit capabilities with intelligent monitoring
- Dual C20 power input connections for redundant power sources
- Professional rack mount power distribution units pdu construction for enterprise environments
- Mixed C13 and C19 outlet configuration for versatile server connectivity
Technical Specifications
| Manufacturer |
Eaton |
| Model Number |
T2235-AB-3551 |
| Type |
ATS Rack PDU (Automatic Transfer Switch) |
| Form Factor |
1U rack mount |
| Input |
Dual C20 connectors |
| Outlets |
8x C13, 1x C19 |
| Max Power |
3.33 kW |
| Voltage Rating |
110-240V single-phase |
| Current Rating |
24A maximum |
| Transfer Type |
Automatic switching between non-phase synchronized AC sources |
| Compatible Systems |
Standard 19-inch server racks and network cabinets |
Frequently Asked Questions
Q: What is an ATS rack PDU used for?
A: An ATS rack PDU provides automatic transfer switching between two independent power sources, ensuring continuous power delivery to critical equipment when the primary source fails or experiences issues.
Q: Is this compatible with standard server racks?
A: Yes, it's engineered for standard 19-inch rack mount installation. The 1U form factor maximizes rack space efficiency while providing enterprise-grade automatic transfer switching capabilities.
Q: What power capacity does this automatic transfer switch support?
A: This switched power distribution unit supports up to 3.33 kW maximum capacity with dual power source inputs — perfect for high-availability server deployments requiring automatic failover protection.
Q: Does this meet data center redundancy requirements?
A: Yes. This Eaton power distribution unit provides automatic transfer switching functionality essential for maintaining uptime in mission-critical data center operations with non-phase synchronized power sources.
ATS Rack PDU for data centers. Eaton automatic transfer switch ePDU with dual C20 inputs, 3.33kW capacity and 1U rack mount design.