This ATS PDU automatic transfer switch is perfect for network administrators and data center managers who need reliable dual input power distribution unit solutions. Our Eaton ATS PDU delivers:
-
Seamless automatic power transfer that ensures zero downtime during power source changes
-
NEMA L5-20R outlet for secure and reliable equipment connections
-
1U rackmount design ensuring space-efficient data center deployment
-
Dual input redundancy for maximum power reliability and uptime
Key Features
-
Automatic transfer switch functionality to eliminate manual power source switching
-
NEMA L5-20R outlet for secure 20-amp equipment connections
- Optimized for 1U rackmount applications
- Consistent dual input power redundancy for critical system protection
-
Space-efficient design to maximize rack utilization
- Industrial-grade construction for reliable data center operation
- Seamless failover protection for mission-critical equipment
Technical Specifications
| Manufacturer |
Eaton |
| Model Number |
T2235-3811 |
| Type |
ATS PDU (Automatic Transfer Switch) |
| Form Factor |
1U rackmount |
| Input Configuration |
Dual input for redundancy |
| Output Outlet |
1-outlet NEMA L5-20R |
| Current Rating |
20A |
| Voltage Rating |
120V |
| Transfer Method |
Automatic |
| Mounting |
19-inch rack mount |
| Operating Environment |
Data center, network closet |
| Compatible Systems |
Network equipment, servers, switches requiring NEMA L5-20 power |
Frequently Asked Questions
Q: What are the benefits of an automatic transfer switch PDU?
A: The ATS PDU automatic transfer switch provides seamless failover between dual power sources, ensuring zero downtime for critical equipment. This eliminates manual intervention and reduces the risk of power interruption.
Q: Is this ATS PDU compatible with standard rack equipment?
A: Yes, it's engineered for 1U rackmount applications. The NEMA L5-20R outlet is compatible with equipment requiring 20-amp power connections with twist-lock security.
Q: How does the dual input redundancy work?
A: Dual input power distribution unit design monitors both power sources continuously — if the primary source fails, it automatically switches to the secondary source without interrupting power to connected equipment.
Q: What maintenance does this ATS PDU require?
A: Minimal maintenance required. Regular visual inspection and periodic testing of transfer functionality ensures optimal performance. The robust design minimizes maintenance intervals for data center environments.