This REPO Rack PDU is perfect for data center managers and facility engineers who need remote emergency power off capabilities with high-capacity power distribution. Our 2U power distribution unit delivers:
-
Remote emergency power off functionality that enables instant shutdown via L21-30 connection
-
2U rack mount design for high-density power distribution applications
-
L21-30 connectivity supporting 30-amp three-phase power distribution
-
Emergency shutdown compliance meeting data center safety and regulatory requirements
Key Features
-
REPO emergency shutdown to provide immediate power cutoff for emergency situations
-
L21-30 input configuration delivering robust 30-amp power capacity
- Optimized for rack mount power distribution unit applications with 2U form factor
- Consistent three-phase power distribution for high-density server deployments
-
Emergency safety compliance meeting NFPA and local fire code requirements
Technical Specifications
| Manufacturer |
Eaton |
| Model Number |
PC975-R |
| Type |
REPO Rack PDU with L21-30 |
| Form Factor |
2U Rack Mount |
| Input Configuration |
L21-30 (30A, 120/208V, 3-phase) |
| Output Configuration |
Multiple outlets with emergency shutdown capability |
| Emergency Function |
Remote Emergency Power Off (REPO) |
| Power Capacity |
30 Amp, 3-phase |
| Safety Features |
Emergency shutdown, fire alarm integration |
| Mounting |
Standard 19-inch rack mount |
| Compatible Systems |
High-density servers, network equipment, storage arrays |
Frequently Asked Questions
Q: How does the L21-30 REPO function work in emergency situations?
A: The L21-30 REPO Rack PDU provides immediate remote emergency power off capabilities, allowing facility managers to cut power instantly to all connected equipment via fire alarm systems or manual emergency controls.
Q: What is the advantage of a 2U form factor for emergency power distribution?
A: This 2U power distribution unit provides high-capacity power handling while maintaining efficient rack space utilization, making it ideal for rack mount power distribution unit applications in critical environments.
Q: What power capacity does the L21-30 connection provide?
A: The L21-30 configuration delivers 30-amp, 120/208V three-phase power, providing substantial capacity for high-density equipment while maintaining emergency shutdown functionality.
Q: Is this REPO PDU compliant with fire safety codes?
A: Yes, this REPO Rack PDU is designed to meet NFPA 70 (National Electrical Code) and local fire code requirements for emergency shutdown systems in data center and critical facility applications.
REPO Rack PDU 2U with L21-30 for emergency power off and 30A distribution.