This rack PDU is perfect for data center administrators and IT professionals who need reliable three-phase power distribution with government compliance requirements. Our Eaton Basic solution delivers:
-
Power distribution unit rack mount design with 0U space-saving installation
-
TAA compliant certification meeting federal acquisition requirements
-
L21-30P input connector for robust three-phase 120/208V power delivery
-
24 5-20R outlets providing flexible power distribution for multiple devices
Key Features
-
Three-phase power distribution with 8.6 kW maximum capacity
-
L21-30P input ensuring secure three-phase connectivity
- Optimized for 19 rack power distribution unit installation
- Consistent 120/208V power delivery for server equipment
-
TAA compliant design to meet government procurement standards
-
10-foot power cord for flexible rack positioning
Technical Specifications
| Manufacturer |
Eaton |
| Model Number |
EBA344-10 |
| Type |
Basic Rack PDU |
| Input |
L21-30P, Three-phase, 120/208V, 24A |
| Maximum Power |
8.6 kW |
| Outlets |
24 x 5-20R NEMA outlets |
| Mounting |
0U rack mountable design |
| Cord Length |
10 feet |
| Compliance |
TAA Compliant |
| Phase Configuration |
Three-phase power distribution |
Frequently Asked Questions
Q: What is a rack PDU and how does three-phase power distribution work?
A: A rack PDU distributes power from a single input source to multiple outlets. This three-phase power distribution unit provides more efficient power delivery and higher capacity than single-phase units, perfect for high-density server environments.
Q: What does TAA compliant mean for government procurement?
A: TAA compliant certification ensures this power distribution unit rack mount meets Trade Agreements Act requirements, making it eligible for federal government purchases and contracts requiring domestic or qualifying country manufacturing.
Q: How many devices can the 24 5-20R outlets support?
A: With 24 5-20R outlets and 8.6 kW capacity, this unit can power multiple servers, network equipment, and other rack-mounted devices. Each 5-20R outlet supports up to 20 amps at 120V for maximum flexibility.
Q: Is the L21-30P input compatible with standard data center power?
A: Yes. The L21-30P input connector is a standard three-phase, four-wire plus ground configuration widely used in data centers for 120/208V power distribution to server racks and network equipment.
Rack PDU for data centers. Eaton Basic L21-30P three-phase power distribution with TAA compliance and 24 5-20R outlets.