This UPS battery module is perfect for data centers and IT professionals who need extended runtime protection for critical systems. Our Eaton 5PXEBM48RTG2 delivers:
-
Server rack battery backup protection that extends runtime during power outages
-
Eaton UPS compatibility for seamless integration with 5PX G2 systems
-
Rack mount battery design ensuring efficient space utilization
-
Extended battery runtime for mission-critical applications
Key Features
-
48V DC battery configuration for optimal power delivery
-
Rack mount design integrates seamlessly with standard server racks
- Optimized for Eaton 5PX G2 UPS systems with hot-swappable capability
- Consistent battery backup performance for critical load protection
-
Tool-free installation for simplified deployment and maintenance
-
LED status indicators for real-time battery monitoring
-
Temperature-compensated charging extending battery lifespan
Technical Specifications
| Manufacturer |
Eaton Corporation |
| Model Number |
5PXEBM48RTG2 |
| Type |
Extended Battery Module (EBM) |
| Voltage |
48V DC nominal |
| Battery Type |
Valve Regulated Lead Acid (VRLA) |
| Form Factor |
2U Rack Mount |
| Dimensions |
17.3" x 16.9" x 3.5" (440 x 430 x 88mm) |
| Weight |
66 lbs (30 kg) |
| Compatibility |
Eaton 5PX G2 UPS Series |
| Operating Temperature |
32°F to 104°F (0°C to 40°C) |
| Storage Temperature |
-4°F to 122°F (-20°C to 50°C) |
| Humidity Range |
0-95% non-condensing |
| Certification |
UL Listed, FCC Part 15 Class A, CE marked |
| Warranty |
3-year manufacturer warranty |
Frequently Asked Questions
Q: Which UPS systems is this extended battery module compatible with?
A: The 5PXEBM48RTG2 is specifically designed for Eaton 5PX G2 UPS systems, providing seamless integration and extended runtime for critical power protection applications.
Q: How much additional runtime does this UPS battery provide?
A: Runtime extension varies based on load, but typically provides 50-100% additional backup time. The server rack battery backup is ideal for extending protection during extended outages.
Q: Can multiple battery modules be connected for even longer runtime?
A: Yes, multiple EBMs can be daisy-chained to achieve maximum runtime extension. Each rack mount battery module adds incremental protection for your critical systems.
Q: What maintenance is required for this battery backup system?
A: Minimal maintenance required. The UPS battery system features automatic temperature compensation and monitoring. Battery replacement is recommended every 3-5 years depending on usage conditions.