Chatsworth eConnect Horizontal 1U Monitored PDU
The eConnect Horizontal 1U monitored PDU is engineered for high-density data center and IT rack environments requiring precise power distribution and real-time monitoring. This monitored power distribution unit delivers nine C19 outlets with 208V output, supporting demanding server and network equipment loads. With 120/208V three-phase input at 30A and a 10 ft cord, the EA-3256-C provides flexible deployment options while enabling detailed power analytics to optimize energy consumption and prevent overload conditions.
Key Features
-
9 C19 Outlets — High-density power distribution for multiple server and equipment connections
-
Monitored Power Management — Real-time power monitoring and analytics for data center optimization
-
120/208V Three-Phase Input — Supports standard three-phase power infrastructure at 30A capacity
-
NEMA L21-30 Plug — Industry-standard connector for reliable power input connections
-
10 ft Cord Length — Flexible positioning within rack environments and data center layouts
-
1U Horizontal Form Factor — Compact rack-mount design maximizes space efficiency
-
208V Output — Delivers consistent power to high-performance IT equipment
-
Overload Protection — Built-in safeguards for equipment and infrastructure protection
Technical Specifications
| Manufacturer |
Strategic Sourcing |
| Part Number |
EA-3256-C |
| Product Type |
Monitored Power Distribution Unit (PDU) |
| Form Factor |
1U Horizontal Rack Mount |
| Input Connector |
NEMA L21-30 |
| Input Voltage |
120/208V Three-Phase |
| Input Current |
30A |
| Output Outlets |
9 x C19 |
| Output Voltage |
208V |
| Cord Length |
10 ft (3 m) |
| Monitoring Capability |
Yes — Real-time power monitoring |
| Mounting |
Standard 19-inch rack |
Frequently Asked Questions
What is a monitored PDU and why do I need one?
A monitored PDU provides real-time visibility into power consumption across individual outlets or outlet groups. This enables data center operators to identify power bottlenecks, balance loads, prevent overload conditions, and optimize energy efficiency — critical for maintaining uptime and controlling operational costs.
How many devices can the eConnect Horizontal 1U PDU support?
The eConnect Horizontal 1U PDU features 9 C19 outlets, each capable of supporting high-power equipment like servers, switches, and storage arrays. Total capacity depends on individual device power requirements but is limited by the 30A input at 120/208V three-phase.
Is this PDU compatible with standard data center racks?
Yes. The 1U horizontal PDU mounts directly into standard 19-inch server racks using industry-standard mounting hardware. The 10 ft cord provides flexibility for positioning near power distribution panels or UPS systems.
What does 120/208V three-phase input mean?
This three-phase power input accepts standard North American three-phase electrical service at 120/208V, commonly found in data centers and enterprise facilities. The 30A capacity supports high-density equipment deployments without requiring additional power infrastructure upgrades.