APC ATS for InRow ACRD101D Dual-Input 48V Power Unit
The APC ATS for InRow ACRD101D is engineered for mission-critical data center environments requiring maximum cooling system resiliency. This dual-input 48V DC power solution connects two separate power sources to your InRow cooling unit, delivering redundancy and eliminating single points of failure. Ideal for enterprises, colocation facilities, and hybrid cloud infrastructures where cooling downtime directly impacts revenue and SLA compliance, this ATS ensures your critical infrastructure stays online.
Key Features
- Dual-input 48V DC power connectivity for enhanced system redundancy
- Automatic failover between two independent power sources
- Seamless integration with InRow ACRD101D indoor cooling units
- CE and UL certified for global compliance and safety standards
- Improves cooling system uptime and operational reliability
- Reduces risk of thermal events from single power source failure
- Supports high-density data center cooling architectures
Technical Specifications
| Specification |
Details |
| Manufacturer |
APC by Schneider Electric |
| Part Number |
ACAC10058 |
| Product Type |
Automatic Transfer Switch (ATS) |
| Input Power |
Dual 48V DC sources |
| Compatible Unit |
InRow ACRD101D Indoor Unit |
| Certifications |
CE, UL |
| Primary Function |
Power redundancy and failover |
Frequently Asked Questions
What is an ATS and why do I need it for my cooling system?
An Automatic Transfer Switch (ATS) enables your InRow cooling unit to draw power from two independent 48V DC sources. If one power source fails, the ATS automatically switches to the backup, preventing cooling interruption and protecting your data center from thermal damage.
How does dual-input 48V power improve cooling system resiliency?
By connecting two separate 48V DC power inputs, you eliminate dependency on a single power feed. The dual-input power configuration ensures continuous cooling operation even during maintenance, power anomalies, or source failures—critical for maintaining uptime in mission-critical environments.
Is the APC ATS ACAC10058 compatible with my existing infrastructure?
Yes, this ATS is specifically designed for the InRow ACRD101D indoor unit and integrates seamlessly into existing APC cooling architectures. Verify your current unit model and consult APC documentation to confirm compatibility with your deployment.
What certifications does this ATS carry?
The APC ATS for InRow ACRD101D holds both CE and UL certifications, ensuring compliance with international electrical safety standards and regulatory requirements for data center and enterprise environments.