{"product_id":"vertiv-vp4n30aj-monitored-rack-pdu","title":"Vertiv VP4N30AJ 30A 208V Monitored Rack PDU","description":"\u003cdiv class=\"product-content\"\u003e\n\u003csection class=\"who-it-for\"\u003e\u003ch1\u003eVertiv VP4N30AJ Monitored Rack PDU\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eVertiv VP4N30AJ\u003c\/strong\u003e is an upgradeable unit level monitored rack power distribution unit engineered for data centers and IT environments requiring precise power visibility and reliable distribution. This \u003cstrong\u003e30A 208V DELTA monitored rPDU\u003c\/strong\u003e delivers 8.6kW of managed power to critical infrastructure with real-time monitoring at input, phase, and circuit levels. Ideal for organizations needing granular power analytics, environmental awareness, and scalable power management across distributed IT equipment, the VP4N30AJ combines robust hardware with intelligent monitoring capabilities.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"key-features\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e30A, 208V DELTA vertical rack PDU with 8.6kW capacity\u003c\/li\u003e\n\u003cli\u003e36 combination C13\/C19 outlets for flexible equipment connectivity\u003c\/li\u003e\n\u003cli\u003eInput and per-phase power monitoring with circuit\/breaker current tracking\u003c\/li\u003e\n\u003cli\u003eUnit level monitored architecture for comprehensive power visibility\u003c\/li\u003e\n\u003cli\u003eOptional environmental monitoring via remote sensors\u003c\/li\u003e\n\u003cli\u003eDaisy chain Ethernet connectivity for multi-unit management\u003c\/li\u003e\n\u003cli\u003eLocal high-visibility display for on-site power status\u003c\/li\u003e\n\u003cli\u003e10 ft power cord with L15-30P connector\u003c\/li\u003e\n\u003cli\u003eUpgradeable design for future capability expansion\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"technical-specs\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eVertiv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eVP4N30AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208V DELTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Capacity\u003c\/td\u003e\n\u003ctd\u003e8.6kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e36 combination C13\/C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cord\u003c\/td\u003e\n\u003ctd\u003e10 ft with L15-30P connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eInput, phase, and circuit level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Monitoring\u003c\/td\u003e\n\u003ctd\u003eOptional remote sensors supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eDaisy chain Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLocal high-visibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eVertical rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"faq\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat is a monitored rack PDU and why do I need one?\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003emonitored rack PDU\u003c\/strong\u003e provides real-time visibility into power consumption across your IT infrastructure. Unlike basic PDUs, the VP4N30AJ tracks input voltage, phase currents, and individual circuit loads, enabling better capacity planning, faster troubleshooting, and reduced downtime in critical environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eCan the Vertiv VP4N30AJ be upgraded or expanded?\u003c\/h3\u003e\n\u003cp\u003eYes, the VP4N30AJ features an upgradeable design that supports future capability enhancements. Its daisy chain Ethernet connectivity allows seamless integration with additional monitored units for centralized power management across multiple racks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat monitoring capabilities does this 30A 208V PDU offer?\u003c\/h3\u003e\n\u003cp\u003eThe VP4N30AJ delivers comprehensive monitoring including input level power usage, per-phase current tracking, circuit\/breaker current monitoring, and optional environmental sensors for temperature and humidity. A local high-visibility display provides immediate on-site status visibility.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eHow many outlets does the VP4N30AJ provide?\u003c\/h3\u003e\n\u003cp\u003eThe unit features 36 combination C13\/C19 outlets, providing flexible connectivity for both standard servers and high-power equipment within your 8.6kW capacity allocation.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"VERTIV","offers":[{"title":"Default Title","offer_id":41762403582027,"sku":"VP4N30AJ","price":2148.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/files\/Vertiv-VP4N30AJ-30A-208V-Monitored-Rack-PDU.png?v=1788320489","url":"https:\/\/www.tecisoft.ca\/products\/vertiv-vp4n30aj-monitored-rack-pdu","provider":"TeciSoft","version":"1.0","type":"link"}