{"product_id":"trendnet-ti-m12-industrial-modbus-gateway","title":"TRENDnet TI-M12 Industrial Modbus Gateway","description":"\u003cdiv class=\"product-content\"\u003e\n\u003csection class=\"product-intro\"\u003e\u003ch1\u003eTRENDnet TI-M12 Industrial Modbus Gateway\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eTRENDnet TI-M12 Industrial Modbus Gateway\u003c\/strong\u003e is a professional-grade networking solution designed to bridge legacy Modbus serial devices with modern Ethernet networks. This \u003cstrong\u003eindustrial Modbus gateway\u003c\/strong\u003e enables seamless communication between RS-232, RS-422, and RS-485 serial devices and your network infrastructure, supporting distances up to 100m (328 ft.) using standard Cat5e cabling. Perfect for manufacturing facilities, HVAC systems, energy management, and industrial automation environments requiring reliable device connectivity and centralized monitoring.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"key-features\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne serial port supporting RS-232\/RS-422\/RS-485 protocols\u003c\/li\u003e\n\u003cli\u003eTwo Fast Ethernet ports for redundant network connectivity\u003c\/li\u003e\n\u003cli\u003eExtended transmission distance up to 100m with Cat5e cabling\u003c\/li\u003e\n\u003cli\u003eWeb-based management interface for easy configuration\u003c\/li\u003e\n\u003cli\u003eDHCP support for simplified network deployment\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range for harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eDIN-rail mountable design for standard industrial installations\u003c\/li\u003e\n\u003cli\u003eModbus protocol translation and gateway functionality\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"technical-specs\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eTRENDnet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eTI-M12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232\/RS-422\/RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2x Fast Ethernet (10\/100 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Distance\u003c\/td\u003e\n\u003ctd\u003e100m (328 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eCat5e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement\u003c\/td\u003e\n\u003ctd\u003eWeb-based interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDHCP\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\/ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eWide industrial range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"faq-section\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat is an industrial Modbus gateway used for?\u003c\/h3\u003e\n\u003cp\u003eAn \u003cstrong\u003eindustrial Modbus gateway\u003c\/strong\u003e connects legacy serial Modbus devices (sensors, controllers, PLCs) to modern Ethernet networks, enabling centralized monitoring, data collection, and remote management without replacing existing equipment. The TI-M12 specifically bridges RS-485 serial devices to your network infrastructure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eHow far can the TRENDnet TI-M12 transmit data?\u003c\/h3\u003e\n\u003cp\u003eThe TI-M12 supports transmission distances up to 100 meters (328 feet) using standard Cat5e cabling, making it ideal for large manufacturing floors, warehouses, and distributed industrial facilities requiring extended connectivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eCan I manage the TI-M12 remotely?\u003c\/h3\u003e\n\u003cp\u003eYes, the TRENDnet TI-M12 features a web-based management interface accessible from any networked device, allowing remote configuration, monitoring, and troubleshooting of your Modbus gateway without on-site visits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eDoes the TI-M12 support DHCP configuration?\u003c\/h3\u003e\n\u003cp\u003eYes, the industrial Modbus gateway includes DHCP support for automatic IP address assignment, simplifying network deployment and reducing manual configuration time in large industrial environments.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"TRENDNET INC","offers":[{"title":"Default Title","offer_id":43066920599627,"sku":"TI-M12","price":364.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/files\/TRENDnet-TI-M12-Industrial-Modbus-Gateway.jpg?v=1789389128","url":"https:\/\/www.tecisoft.ca\/products\/trendnet-ti-m12-industrial-modbus-gateway","provider":"TeciSoft","version":"1.0","type":"link"}