{"product_id":"eaton-93pm-208v-30kw-n1-ups-system","title":"Eaton 93PM 208V 30kW N+1 UPS System","description":"\u003cdiv class=\"product-content\"\u003e\n\u003csection class=\"who-its-for\"\u003e\u003ch1\u003eEaton 93PM 208V 30kW N+1 Uninterruptible Power Supply\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eEaton 93PM 208V 30kW\u003c\/strong\u003e is a three-phase uninterruptible power system engineered for mission-critical IT and data center environments requiring high-efficiency power protection. This \u003cstrong\u003eN+1 redundant UPS configuration\u003c\/strong\u003e delivers 30 kW of continuous power capacity with all components included, minus batteries, making it ideal for organizations that need scalable, reliable backup power without compromise. Perfect for enterprises protecting servers, networking equipment, and critical infrastructure from power interruptions and voltage fluctuations.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"key-features\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e30 kW power capacity with N+1 redundancy architecture for maximum uptime\u003c\/li\u003e\n\u003cli\u003eThree-phase 208V input\/output for enterprise data center applications\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency power conversion minimizes energy waste and operating costs\u003c\/li\u003e\n\u003cli\u003eModular design optimizes space utilization in constrained environments\u003c\/li\u003e\n\u003cli\u003eAll required components included for seamless integration into existing systems\u003c\/li\u003e\n\u003cli\u003eScalable UPS solution supporting mission-critical infrastructure protection\u003c\/li\u003e\n\u003cli\u003eAdvanced monitoring and management capabilities for remote oversight\u003c\/li\u003e\n\u003cli\u003eHot-swappable modules enable maintenance without downtime\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"technical-specs\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"10\"\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Series\u003c\/td\u003e\n\u003ctd\u003e93PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e9GC306A029B00R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Capacity\u003c\/td\u003e\n\u003ctd\u003e30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208V Three-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e208V Three-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Configuration\u003c\/td\u003e\n\u003ctd\u003eN+1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Included\u003c\/td\u003e\n\u003ctd\u003eNo (All other components included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eData Centers, IT Infrastructure, Critical Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"faq\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat does N+1 redundancy mean in a UPS system?\u003c\/h3\u003e\n\u003cp\u003eN+1 redundancy means the UPS system has one additional module beyond what is required for normal operation. If one module fails, the remaining module continues protecting your equipment without interruption, ensuring zero downtime for mission-critical applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhy choose a 30kW three-phase UPS for data centers?\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003e30kW three-phase UPS\u003c\/strong\u003e provides substantial power capacity for large server installations and distributed IT infrastructure. Three-phase systems are more efficient and cost-effective than single-phase alternatives for enterprise-scale deployments, reducing energy consumption and operational expenses.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eCan I add batteries to the Eaton 93PM 30kW later?\u003c\/h3\u003e\n\u003cp\u003eYes. This configuration ships without batteries but includes all other components. You can integrate compatible battery modules later to extend runtime protection as your backup power requirements evolve.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat makes the 93PM series suitable for high-efficiency environments?\u003c\/h3\u003e\n\u003cp\u003eThe Eaton 93PM delivers industry-leading power conversion efficiency, minimizing heat generation and energy waste. This reduces cooling costs and environmental impact while maximizing runtime on backup power, making it ideal for organizations prioritizing operational efficiency and sustainability.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":41627168309323,"sku":"9GC306A029B00R1","price":67606.0,"currency_code":"CAD","in_stock":true}],"url":"https:\/\/www.tecisoft.ca\/products\/eaton-93pm-208v-30kw-n1-ups-system","provider":"TeciSoft","version":"1.0","type":"link"}