{"product_id":"doble-f6080-field-calibration-unit","title":"Doble F6080 Field Calibration Unit","description":"\u003cdiv class=\"product-content\"\u003e\n\u003csection class=\"product-intro\"\u003e\u003ch1\u003eDoble F6080 Field Calibration Unit\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eDoble F6080 Field Calibration Unit\u003c\/strong\u003e is a portable, high-accuracy calibration solution designed to verify and maintain the performance of Doble F6150 and related protection test instruments. This field calibration unit delivers precise voltage and current measurement, accurate frequency measurement, and logic input timing verification—ensuring your protection test equipment remains properly calibrated for reliable field testing. With RS-232 connectivity, wide operating temperature range, and robust portable design, the F6080 is engineered for demanding field service and high-reliability applications where measurement accuracy is critical.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"key-features\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-accuracy voltage and current measurement for protection test instrument calibration\u003c\/li\u003e\n\u003cli\u003ePrecise frequency measurement and logic input timing verification\u003c\/li\u003e\n\u003cli\u003eRS-232 control interface for seamless integration with calibration systems\u003c\/li\u003e\n\u003cli\u003ePortable field-ready design with robust construction\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range for diverse field environments\u003c\/li\u003e\n\u003cli\u003e100–240 V, 50\/60 Hz universal power supply compatibility\u003c\/li\u003e\n\u003cli\u003eDependable performance for high-reliability testing applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"specifications\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"8\"\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDoble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\/Part Number\u003c\/td\u003e\n\u003ctd\u003eF6080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eField Calibration Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Application\u003c\/td\u003e\n\u003ctd\u003eProtection Test Instrument Calibration \u0026amp; Verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Instruments\u003c\/td\u003e\n\u003ctd\u003eDoble F6150 and related protection test instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Capabilities\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, Frequency, Logic Input Timing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003ePortable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003eWide range for field use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"faq\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat is the F6080 Field Calibration Unit used for?\u003c\/h3\u003e\n\u003cp\u003eThe Doble F6080 is used to calibrate and verify the accuracy of Doble F6150 and related protection test instruments in the field. It ensures that your test equipment maintains proper calibration for accurate and reliable testing performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eHow does the F6080 connect to test equipment?\u003c\/h3\u003e\n\u003cp\u003eThe F6080 Field Calibration Unit connects via \u003cstrong\u003eRS-232 control interface\u003c\/strong\u003e to a control computer, enabling automated calibration routines and verification procedures for protection test instruments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eIs the F6080 suitable for portable field calibration?\u003c\/h3\u003e\n\u003cp\u003eYes. The F6080 features a portable design with robust construction and wide operating temperature range, making it ideal for field service applications where protection test instrument calibration and verification are required on-site.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat power requirements does the F6080 have?\u003c\/h3\u003e\n\u003cp\u003eThe F6080 Field Calibration Unit operates from a universal 100–240 V, 50\/60 Hz power supply, providing flexibility for use in different geographic locations and field environments.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Kanto Living Inc","offers":[{"title":"Default Title","offer_id":43050426138699,"sku":"F6080","price":205.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/files\/Doble-F6080-Field-Calibration-Unit.jpg?v=1789385024","url":"https:\/\/www.tecisoft.ca\/products\/doble-f6080-field-calibration-unit","provider":"TeciSoft","version":"1.0","type":"link"}