{"product_id":"bb-smartworx-485tbled-rs232-rs485-converter","title":"B+B SmartWorx 485TBLED RS-232 to RS-485 Converter","description":"\u003cdiv class=\"product-content\"\u003e\n\u003csection class=\"who-and-why\"\u003e\u003ch1\u003eB+B SmartWorx 485TBLED RS-232 to RS-485 Converter\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003e485TBLED RS-232 to RS-485 converter\u003c\/strong\u003e is engineered for industrial and commercial environments requiring dependable long-distance serial communication. This \u003cstrong\u003eserial converter\u003c\/strong\u003e transforms unbalanced, full-duplex RS-232 signals into balanced, full- or half-duplex RS-422\/RS-485 signals, enabling seamless integration between legacy RS-232 equipment and modern RS-422\/RS-485 networks. Perfect for manufacturing facilities, SCADA systems, and distributed control applications where signal integrity and extended cable runs are critical.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"key-features\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConverts RS-232 to RS-422\/RS-485 balanced signals for extended transmission distances\u003c\/li\u003e\n\u003cli\u003eSupports full-duplex and half-duplex operation modes\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade design for reliable long-distance serial communication\u003c\/li\u003e\n\u003cli\u003eEnables integration of RS-232 devices into RS-485 networks\u003c\/li\u003e\n\u003cli\u003eCompact form factor suitable for DIN rail or panel mounting\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation protection for noise immunity\u003c\/li\u003e\n\u003cli\u003eLow power consumption for continuous operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"technical-specs\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eB+B SmartWorx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e485TBLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eBB-485TBLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eRS-232 (unbalanced, full-duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eRS-422\/RS-485 (balanced, full\/half-duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eSerial (asynchronous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 4,000 feet (1,200 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 115.2 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12VDC (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"faq\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat is an RS-232 to RS-485 converter used for?\u003c\/h3\u003e\n\u003cp\u003eAn \u003cstrong\u003eRS-232 to RS-485 converter\u003c\/strong\u003e bridges legacy RS-232 equipment with modern RS-485 networks, enabling long-distance serial communication in industrial automation, SCADA, and control systems where extended cable runs and noise immunity are essential.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eHow does the 485TBLED improve serial communication reliability?\u003c\/h3\u003e\n\u003cp\u003eThe B+B SmartWorx 485TBLED converts unbalanced RS-232 signals to balanced RS-422\/RS-485 signals, which are inherently more resistant to electromagnetic interference and support transmission distances up to 4,000 feet, ensuring reliable long-distance serial communication in harsh industrial environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eCan the 485TBLED operate in both full-duplex and half-duplex modes?\u003c\/h3\u003e\n\u003cp\u003eYes, this \u003cstrong\u003eserial converter\u003c\/strong\u003e supports both full-duplex and half-duplex operation, providing flexibility to match your network topology and application requirements for RS-422\/RS-485 communications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eIs galvanic isolation included in the 485TBLED?\u003c\/h3\u003e\n\u003cp\u003eThe 485TBLED features galvanic isolation protection, which prevents ground loop noise and protects connected equipment from voltage spikes, making it ideal for industrial applications requiring robust long-distance serial communication.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"B+B SMARTWORX","offers":[{"title":"Default Title","offer_id":41637505237067,"sku":"BB-485TBLED","price":158.0,"currency_code":"CAD","in_stock":true}],"url":"https:\/\/www.tecisoft.ca\/products\/bb-smartworx-485tbled-rs232-rs485-converter","provider":"TeciSoft","version":"1.0","type":"link"}