{"product_id":"apc-galaxy-vs-parallel-maintenance-bypass-panel-10-30kw-400v","title":"APC Galaxy VS Parallel Maintenance Bypass Panel 10-30kW","description":"\u003cdiv class=\"product-content\"\u003e\n\u003csection class=\"who-its-for\"\u003e\u003ch1\u003eAPC Galaxy VS Parallel Maintenance Bypass Panel for Dual UPS Systems\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eGalaxy VS Parallel Maintenance Bypass Panel\u003c\/strong\u003e (GVSBPAR10K30H) is engineered for organizations requiring uninterrupted power during UPS maintenance. Designed for two \u003cstrong\u003eGalaxy VS UPS systems\u003c\/strong\u003e in the 10–30 kW range at 400V, this wall-mounted bypass solution enables safe isolation and servicing of critical power equipment without interrupting load power delivery. Ideal for data centers, server rooms, and mission-critical facilities where downtime is not an option, this \u003cstrong\u003eparallel maintenance bypass panel\u003c\/strong\u003e ensures continuous operation while your UPS units receive essential maintenance and support.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"key-features\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDual UPS parallel configuration support for 10–30 kW systems\u003c\/li\u003e\n\u003cli\u003e400V three-phase input and output compatibility\u003c\/li\u003e\n\u003cli\u003eWall-mounted design for space-efficient installation\u003c\/li\u003e\n\u003cli\u003eSafe isolation capability for individual UPS maintenance\u003c\/li\u003e\n\u003cli\u003eMaintains load power during service operations\u003c\/li\u003e\n\u003cli\u003ePart of the APC Galaxy VS ecosystem for seamless integration\u003c\/li\u003e\n\u003cli\u003eEngineered for critical power environments and high availability\u003c\/li\u003e\n\u003cli\u003eReliable parallel switching for redundant power delivery\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"technical-specs\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eGVSBPAR10K30H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eParallel Maintenance Bypass Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible UPS Range\u003c\/td\u003e\n\u003ctd\u003e10–30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\/Output Voltage\u003c\/td\u003e\n\u003ctd\u003e400V, three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eDual Galaxy VS UPS systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eSafe UPS isolation and maintenance bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"faq\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat is a parallel maintenance bypass panel used for?\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eparallel maintenance bypass panel\u003c\/strong\u003e allows you to safely isolate one or both UPS units for maintenance, repair, or replacement while the connected load remains powered through the bypass path. This eliminates costly downtime in critical power environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eCan this bypass panel work with a single UPS system?\u003c\/h3\u003e\n\u003cp\u003eThe GVSBPAR10K30H is specifically designed for two Galaxy VS UPS systems operating in parallel. For single UPS configurations, alternative bypass solutions may be more appropriate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat power range does this maintenance bypass panel support?\u003c\/h3\u003e\n\u003cp\u003eThis panel supports dual Galaxy VS UPS systems in the \u003cstrong\u003e10–30 kW power range\u003c\/strong\u003e at 400V, making it suitable for mid-sized data centers and critical infrastructure applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eHow does the wall-mounted design benefit installation?\u003c\/h3\u003e\n\u003cp\u003eThe wall-mounted configuration saves valuable floor space in server rooms and data centers while maintaining easy access for monitoring and maintenance operations on the bypass panel itself.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"APC BY SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":41695639765067,"sku":"GVSBPAR10K30H","price":7318.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1824\/0789\/files\/APC-Galaxy-VS-Parallel-Maintenance-Bypass-Panel-10-30kW.jpg?v=1788303911","url":"https:\/\/www.tecisoft.ca\/products\/apc-galaxy-vs-parallel-maintenance-bypass-panel-10-30kw-400v","provider":"TeciSoft","version":"1.0","type":"link"}